| Diverter
/ Flap Damper |
 |
Click Images to Expand |
 |
Diverters
/Flap Dampers are primarily used in gas turbine
applications with heat recovery steam generators (HRSG).
A diverter damper is designed with one inlet and two
outlets. The outlets are normally at right angles from
each other. The blade pivots from one end rotating 90
degrees to close off one of the two outlets. This system
always allows for an escape route for the flue gas,
therefore protecting any upstream equipment from bottlenecking
the turbine. Diverters can be supplied in a low leak
or zero leak application. They are perfect for clean
applications that require low-pressure drop and good
isolation. |
| |
|